Plant Productivity
98,32%
/ 99,0% Țintă
Total Downtime
36,4
Hours
Plus 90 zile
Incident Count
29
Events
Recent activity
Downtime Breakdown by Category
| Category | Events | Hours | Impact % |
|---|---|---|---|
|
No Materials
|
12 | 11,8h |
32,6%
|
|
Human Error
|
5 | 2,7h |
7,3%
|
|
Electrical
|
8 | 15,1h |
41,6%
|
|
Mechanical
|
4 | 6,8h |
18,6%
|
|
Total
|
29 | 36,4h |
100%
|
Detailed Error Log
29 records| Type & Status | Timeline | Durată | Description |
|---|---|---|---|
|
Human Error
Resolved
|
06.04.2026
19:35:40
→
06.04.2026
20:08:40
|
33m 0s
Total Downtime
|
Calibration check triggered by operator |
|
Mechanical
Resolved
|
06.04.2026
16:31:56
→
06.04.2026
19:23:56
|
2h 52m
Total Downtime
|
Conveyor belt tracking misalignment |
|
Electrical
Resolved
|
02.04.2026
14:49:54
→
02.04.2026
16:38:54
|
1h 49m
Total Downtime
|
Sensor cable damage on aggregate weigher |
|
No Materials
Resolved
|
02.04.2026
12:34:12
→
02.04.2026
12:57:12
|
23m 0s
Total Downtime
|
Sand moisture sensor fault - manual check required |
|
Electrical
Resolved
|
01.04.2026
20:33:09
→
01.04.2026
22:30:00
|
1h 56m
Total Downtime
|
Mixer motor overcurrent protection activated |
|
No Materials
Resolved
|
01.04.2026
14:31:30
→
01.04.2026
15:46:30
|
1h 15m
Total Downtime
|
Aggregate bin S1 empty - waiting for delivery |
|
Electrical
Resolved
|
31.03.2026
16:41:20
→
31.03.2026
19:16:20
|
2h 35m
Total Downtime
|
Power supply fluctuation - system restart |
|
No Materials
Resolved
|
31.03.2026
14:55:20
→
31.03.2026
15:11:20
|
16m 0s
Total Downtime
|
Cement silo low level alarm - resupply in progress |
|
No Materials
Resolved
|
31.03.2026
10:57:52
→
31.03.2026
11:49:52
|
52m 0s
Total Downtime
|
Additive container needs replacement |
|
No Materials
Resolved
|
27.03.2026
11:27:47
→
27.03.2026
12:39:47
|
1h 12m
Total Downtime
|
Aggregate bin S1 empty - waiting for delivery |
|
Mechanical
Resolved
|
26.03.2026
15:26:59
→
26.03.2026
18:27:59
|
3h 1m
Total Downtime
|
Mixer blade wear - scheduled replacement |
|
Human Error
Resolved
|
26.03.2026
10:10:29
→
26.03.2026
10:16:29
|
6m 0s
Total Downtime
|
Wrong recipe selected - batch discarded |
|
No Materials
Resolved
|
24.03.2026
09:59:39
→
24.03.2026
10:15:39
|
16m 0s
Total Downtime
|
Sand moisture sensor fault - manual check required |
|
Electrical
Resolved
|
20.03.2026
11:49:46
→
20.03.2026
12:54:46
|
1h 5m
Total Downtime
|
Conveyor belt motor thermal trip |
|
Human Error
Resolved
|
20.03.2026
11:19:11
→
20.03.2026
11:55:11
|
36m 0s
Total Downtime
|
Operator emergency stop - false alarm |
|
Electrical
Resolved
|
19.03.2026
15:54:48
→
19.03.2026
18:04:48
|
2h 10m
Total Downtime
|
Mixer motor overcurrent protection activated |
|
Human Error
Resolved
|
19.03.2026
13:41:36
→
19.03.2026
14:14:36
|
33m 0s
Total Downtime
|
Wrong recipe selected - batch discarded |
|
No Materials
Resolved
|
18.03.2026
19:42:28
→
18.03.2026
21:30:00
|
1h 47m
Total Downtime
|
Water supply pressure insufficient |
|
Electrical
Resolved
|
18.03.2026
16:05:12
→
18.03.2026
17:22:12
|
1h 17m
Total Downtime
|
Mixer motor overcurrent protection activated |
|
Electrical
Resolved
|
18.03.2026
15:22:58
→
18.03.2026
16:40:58
|
1h 18m
Total Downtime
|
Mixer motor overcurrent protection activated |
|
No Materials
Resolved
|
14.03.2026
18:17:06
→
14.03.2026
19:49:06
|
1h 32m
Total Downtime
|
Bitumen tank temperature too low for pumping |
|
Electrical
Resolved
|
13.03.2026
18:27:44
→
13.03.2026
21:23:44
|
2h 56m
Total Downtime
|
Control panel UPS battery low |
|
Mechanical
Resolved
|
12.03.2026
20:57:57
→
12.03.2026
21:30:00
|
32m 3s
Total Downtime
|
Aggregate weigh hopper calibration drift |
|
No Materials
Resolved
|
12.03.2026
09:17:58
→
12.03.2026
10:49:58
|
1h 32m
Total Downtime
|
Aggregate bin S1 empty - waiting for delivery |
|
Human Error
Resolved
|
09.03.2026
20:04:53
→
09.03.2026
20:56:53
|
52m 0s
Total Downtime
|
Manual override left engaged |
|
Mechanical
Resolved
|
09.03.2026
16:11:18
→
09.03.2026
16:31:18
|
20m 0s
Total Downtime
|
Conveyor belt tracking misalignment |
|
No Materials
Resolved
|
06.03.2026
09:05:15
→
06.03.2026
09:50:15
|
45m 0s
Total Downtime
|
Sand moisture sensor fault - manual check required |
|
No Materials
Resolved
|
05.03.2026
20:23:59
→
05.03.2026
21:28:59
|
1h 5m
Total Downtime
|
Filler silo empty - delivery delayed |
|
No Materials
Resolved
|
05.03.2026
18:37:37
→
05.03.2026
19:32:37
|
55m 0s
Total Downtime
|
Sand moisture sensor fault - manual check required |
Timeline
Durată
Description
Calibration check triggered by operator
Timeline
Durată
Description
Conveyor belt tracking misalignment
Timeline
Durată
Description
Sensor cable damage on aggregate weigher
Timeline
Durată
Description
Sand moisture sensor fault - manual check required
Timeline
Durată
Description
Mixer motor overcurrent protection activated
Timeline
Durată
Description
Aggregate bin S1 empty - waiting for delivery
Timeline
Durată
Description
Power supply fluctuation - system restart
Timeline
Durată
Description
Cement silo low level alarm - resupply in progress
Timeline
Durată
Description
Additive container needs replacement
Timeline
Durată
Description
Aggregate bin S1 empty - waiting for delivery
Timeline
Durată
Description
Mixer blade wear - scheduled replacement
Timeline
Durată
Description
Wrong recipe selected - batch discarded
Timeline
Durată
Description
Sand moisture sensor fault - manual check required
Timeline
Durată
Description
Conveyor belt motor thermal trip
Timeline
Durată
Description
Operator emergency stop - false alarm
Timeline
Durată
Description
Mixer motor overcurrent protection activated
Timeline
Durată
Description
Wrong recipe selected - batch discarded
Timeline
Durată
Description
Water supply pressure insufficient
Timeline
Durată
Description
Mixer motor overcurrent protection activated
Timeline
Durată
Description
Mixer motor overcurrent protection activated
Timeline
Durată
Description
Bitumen tank temperature too low for pumping
Timeline
Durată
Description
Control panel UPS battery low
Timeline
Durată
Description
Aggregate weigh hopper calibration drift
Timeline
Durată
Description
Aggregate bin S1 empty - waiting for delivery
Timeline
Durată
Description
Manual override left engaged
Timeline
Durată
Description
Conveyor belt tracking misalignment
Timeline
Durată
Description
Sand moisture sensor fault - manual check required
Timeline
Durată
Description
Filler silo empty - delivery delayed
Timeline
Durată
Description